The following options are available:
| • | Optimization:
Optimization level of the compiler (gcc). |
| • | Enable signal interface (always active):
Enables signal interface to monitor all signals of the running SCALE-RT model.
The checkbox 'Signal storage reuse' on the 'Optimization pane' should be unselected. |
| • | Export only signals with test points:
Reduces the available signals of the running model to signals with test points.
To create a test point place the cursor on a signal line, press the right mouse button and select 'Signal Properties...'.
Then select the checkbox 'Test point'. |


| • | Enable parameter tuning:
Enables parameter tuning of the running SCALE-RT model. If 'Inline parameters' is selected on the 'Optimization pane', only tunable global parameters will be available.
If 'Inline parameters' is not selected all tunable parameters will be available. |
| • | Enable state interface:
Enables state interface to monitor all states of the running SCALE-RT model. |
| • | GenRTModel (always active) |
|